CO2 incubator ICO105, 107 l, 20–50 °C, CO2 control 0–20%

The picture may be different from the article and can include supply, which is not in the standard scope.

CO2 incubator ICO105; 108 l; working temperature range 5 °C above room temperature to 50 °C; setting temperature range 20 °C to 50 °C; with CO2 control – using dual-beam NDIR measurement – adjustable from 0% to 20%; Humidity limitation via Peltier element; when the water tank is filled and inserted, limits the relative humidity inside the chamber to 93% RH ± 2.5%; electronic microprocessor temperature controller with Pt1000 and self-diagnostic system; fully insulated stainless steel door and inner glass door; 6-sided all-round heating; Stainless steel housing and chamber; with 1 stainless steel water tray; with 1 stainless steel perforated shelf; multiple over-temperature protection/under-temperature alarm; pre-programmed sterilisation programme; factory calibration certificate for +37 °C, 5% CO2; patterned stainless steel housing: 708 x 683 x 586 mm; Stainless steel interior: 560 x 480 x 400 mm; Voltage: 230 V, 50/60 Hz; max. power input: approx. 1450 W
Description value
WEEE obligation: Yes
WEEE registration number: DE66812464
WEEE brand according to EAR register: Memmert
WEEE type of equipment: Large equipment for use in other than private households only

External measuring instrument with additional measuring head for temperature and External...

Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of...

USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use USB User-ID...

Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f Subframe (622 mm...

Subframe (130 mm high); sizes 150/240: only in combination with the correspondin Subframe (130 mm...

Water dish Water dish

3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile co 3 HEPA14-filters...

HEPA14-filter for chamber according to EN 1822, packed in sterile condition, inc HEPA14-filter...

Door with lock and key (safety lock) Door with lock and key (safety lock)

Door hinged on the left Door hinged on the left

Integrated battery backup: Uninterrupted power supply to the entire display unit Integrated...

MobileALERT, notification by SMS in case of any error or alarm of the device (re MobileALERT,...

MobileALERT for up to 4 alarm messages (requires option H6 and K6 or K7); alarm MobileALERT for...

Calibration // three CO2 values (5% CO2, 7% CO2, 10% CO2 at +37 °C) Calibration // three CO2...

IQ/OQ/PQ checklist IQ/OQ/PQ checklist

Calibration // temperature, humidity and CO2 value - freely selectable Calibration //...

Calibration // temperature, humidity, CO2 and O2 value - freely selectable Calibration //...

IQ/OQ document incl. empty chamber distribution measurement according to DIN 128 IQ/OQ document...

IQ/OQ qualification incl. empty chamber distribution measurement according to DI IQ/OQ...

IQ/OQ qualification // additional temperature, humidity and CO2 value - freely s IQ/OQ...

IQ/OQ qualification incl. empty chamber distribution measurement according to DI IQ/OQ...

IQ/OQ qualification // additional temperature, humidity, CO2 and O2 value - free IQ/OQ...

PQ qualification; incl. documentation PQ qualification; incl. documentation

CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor CO2 pressure reducing valve...

Ethernet connection cable 5 m for computer interface Ethernet connection cable 5 m for computer...

USB-Ethernet adapter USB-Ethernet adapter

Perforated stainless steel shelf Perforated stainless steel shelf

DAkkS calibration according to method C (DKD-R 5-7) // temperature and humidity DAkkS...

DAkkS calibration according to method C/A (DKD-R 5-7) // additional temperature DAkkS...

Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by si Entry port...

Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme Basic licence...

Warranty extension by 1 year // I: Appliance sizes: 450, 750; ICO: Appliance siz Warranty...

Potential-free contact for combination error message (e.g. supply failure, senso Potential-free...

Heated inner door with partitioned glass doors; sizes 105/150/240 has 2/3/4 part Heated inner...

Peltier cooling unit enables a working temperature of +37 °C even at higher ambi Peltier cooling...

Capacitive humidity sensor for measuring and displaying the relative humidity Capacitive humidity...

Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh), Active...

Calibration // temperature, humidity and CO2 value - freely selectable Calibration //...

Calibration // additional temperature, humidity and CO2 value - freely selectabl Calibration //...

Maintenance on site; for appliances with active humidity control (option K7) Maintenance on site;...

Maintenance on site (maintenance contract); for appliances with active humidity Maintenance on...

Maintenance on site; for appliances with passive humidity control Maintenance on site; for...

Maintenance on site (maintenance contract); for appliances with passive humidity Maintenance on...

Two gas connections with quick release connectors for automatic switch-over of g Two gas...

Electropolished interior Electropolished interior

Control of oxygen concentration by introducing nitrogen; setting range 1–20% O2; Control of...

4 - 20 mA current loop interface; O2 controller, actual value (0 to 25 % O2 = 4 4 - 20 mA...

4 - 20 mA current loop interface; Temperature controller, actual value (0 to +70 4 - 20 mA...

4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 % 4 - 20 mA...

4 - 20 mA current loop interface; CO2 controller, actual value (0 to 25 % CO2 = 4 - 20 mA...

Voltage 115 V, 50/60 Hz Voltage 115 V, 50/60 Hz

Central water supply, with filter cartridges for connection to the domestic wate Central water...

Central water supply, without filter cartridges for connection to the domestic w Central water...

CO2-Incubator ICO105med, 107l, 18-50°C, CO2 control 0-20% CO2 Incubator ICO105med, medical...

External measuring instrument with additional measuring head for temperature and External...

Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of...

USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use USB User-ID...

Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used f Subframe (622 mm...

Subframe (130 mm high); sizes 150/240: only in combination with the correspondin Subframe (130 mm...

Water dish Water dish

3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile co 3 HEPA14-filters...

HEPA14-filter for chamber according to EN 1822, packed in sterile condition, inc HEPA14-filter...

IQ/OQ/PQ checklist IQ/OQ/PQ checklist

IQ/OQ document incl. empty chamber distribution measurement according to DIN 128 IQ/OQ document...

IQ/OQ qualification incl. empty chamber distribution measurement according to DI IQ/OQ...

IQ/OQ qualification // additional temperature, humidity and CO2 value - freely s IQ/OQ...

IQ/OQ qualification incl. empty chamber distribution measurement according to DI IQ/OQ...

IQ/OQ qualification // additional temperature, humidity, CO2 and O2 value - free IQ/OQ...

PQ qualification; incl. documentation PQ qualification; incl. documentation

CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor CO2 pressure reducing valve...

Ethernet connection cable 5 m for computer interface Ethernet connection cable 5 m for computer...

USB-Ethernet adapter USB-Ethernet adapter

Perforated stainless steel shelf Perforated stainless steel shelf

DAkkS calibration according to method C (DKD-R 5-7) // temperature and humidity DAkkS...

DAkkS calibration according to method C/A (DKD-R 5-7) // additional temperature DAkkS...

Basic licence for AtmoCONTROL FDA and myChamber Control FDA. Meets the requireme Basic licence...

Warranty extension by 1 year // Im, Um, S: Appliance sizes: 450, 750; ICOmed: Ap Warranty...

Heated inner door with partitioned glass doors; sizes 105/150/240 has 2/3/4 part Heated inner...

Capacitive humidity sensor for measuring and displaying the relative humidity Capacitive humidity...

Active microprocessor control for humidifying and dehumidifying (40 - 97 % rh), Active...

Calibration // temperature, humidity and CO2 value - freely selectable Calibration //...

Calibration // additional temperature, humidity and CO2 value - freely selectabl Calibration //...

Maintenance on site; for appliances with active humidity control (option K7) Maintenance on site;...

Maintenance on site (maintenance contract); for appliances with active humidity Maintenance on...

Maintenance on site; for appliances with passive humidity control Maintenance on site; for...

Maintenance on site (maintenance contract); for appliances with passive humidity Maintenance on...

Electropolished interior Electropolished interior

Control of oxygen concentration by introducing nitrogen; setting range 1–20% O2; Control of...

Voltage 115 V, 50/60 Hz Voltage 115 V, 50/60 Hz

Central water supply, with filter cartridges for connection to the domestic wate Central water...